Product category

Commercial Refrigeration Equipment

Cold chain performance decides shelf life, waste and inspection results. We specify refrigeration by temperature band, product load, ambient conditions and the refrigerant rules of your market. Refrigeration equipment covers upright cabinets, undercounter chillers and freezers, blast chillers and modular cold rooms, with refrigerant and voltage configured for each destination market.

Applicable buyers: Restaurants, hotels, cafés, bakeries and central kitchens

CE and UKCA are the conformity schemes commonly referenced for EU/UK projects. This is a requirement note, not a statement that a certificate is held; copies and model scope are provided on request.

Refrigeration is the line buyers regret fastest when it is undersized. We size it from the product load and the service day, not from a catalogue page.

  • EU / UK
  • North America
  • Southeast Asia
  • Configuration per market
201 stainless steel commercial refrigeration equipment with upright chillers, undercounter units and a blast chiller
Range structure

Configuration families in this category

The model list is to be confirmed. These are the configuration families buyers most often request; send your required capacity and we will match them to current models.

Upright refrigerators and freezers

Single, two- and four-door cabinets in chiller and freezer bands for daily service stock.

Undercounter and prep counters

Worktop refrigeration that keeps ingredients within reach on the line, with GN-compatible pan configurations.

Blast chillers and freezers

Rapid chilling for cook-chill production, sized by batch weight and the cycle time your process allows.

Cold rooms and walk-ins

Modular panels, doors and condensing units assembled to the room dimensions and access you provide.

Typical technical parameters

Values below are typical configuration ranges for the category, not a verified model specification.

Refrigeration Equipment — typical technical parameters
ParameterValue / configuration
Temperature bandsChiller and freezer bands stated per model; blast chilling where specified
RefrigerantR290 where applicable; alternatives confirmed against market rules
Supply voltage220–240V / 50Hz (EU/UK/SEA); 110–120V / 60Hz (North America); three-phase options for larger units
Structure material201 stainless steel
Insulation and doorsSolid or glass doors; gaskets and insulation confirmed per model
Defrost and controlAutomatic defrost with digital temperature display and alarms
Compliance documentationCE / UKCA (EU/UK), ETL / UL / NSF (North America) — verified copies on request
Verified model valuesTo be confirmed — supplied in the official spec sheet

Typical configuration ranges only. Model-specific verified values, dimensions and certificate numbers are supplied in the official spec sheet on request.

Market build

Certification, voltage and gas notes by market

Compliance requirements differ by destination. Confirm them before the quotation so the refrigeration equipment build, documents and price are correct the first time.

EU / UK

CE and UKCA documentation, 220–240V / 50Hz supply, and builds aligned with the applicable gas appliance regulation. Ask for the certificate copy covering the exact model.

North America

ETL / UL / NSF references as applicable, 110–120V / 60Hz or three-phase supply, and ANSI/CSA gas considerations. Confirm the inspection authority for your state or province.

Southeast Asia

LPG-dominant gas configuration where applicable, 220–240V / 50Hz with three-phase options, and high-ambient builds. Confirm local import and installation requirements early.

Compliance noteCertificate numbers, issuing bodies and validity dates are confirmed in the official copies. Nothing on this page claims a specific certificate is held until it is verified.
Where it is used

Typical applications for this category

Three settings buyers usually describe to us, and how the specification changes in each.

Restaurant kitchens

A restaurant needs commercial refrigeration within reach of every station. Undercounter chillers and prep counters keep the line moving while upright cabinets hold the service stock.

Central kitchens and commissaries

Cook-chill production depends on blast chilling that finishes inside the process window, followed by commercial refrigeration sized to the dispatch plan rather than to the room available.

Distributors and food plants

Cold storage is sized from throughput and dwell time. We confirm the temperature band, door type and refrigerant rules before quoting the commercial refrigeration equipment.

Selection checklist

  • Product load, turnover and the temperature band each item needs
  • Kitchen ambient temperature and how often doors are opened
  • Available floor area, access width and the route to the final position
  • Refrigerant, voltage and documentation rules in your market
  • Defrost drainage, ventilation space and service access
Inquire now

Tell us what you need in this category

Send your capacity, voltage, gas or refrigerant requirement and destination port. We will return matched models, compliance notes and a quotation.

FAQ

Refrigeration Equipment — common questions

Short, direct answers for buyers shortlisting this category.

Which refrigerant will my market accept?

It depends on the destination and the equipment. R290 is used where the applicable charge and installation rules allow it; oil and alternative refrigerants are confirmed case by case. Tell us the country and the equipment list and we will confirm the build.

Chiller and freezer in one cabinet — is that possible?

Yes, combined cabinets exist in both bands, but each side carries its own temperature band and control. Send the products you plan to store and we will confirm whether a combined unit or two separate cabinets is the better fit.

How do I size cold storage for my covers?

Start from the products stored per service, their volume and how long they stay in storage. Send daily covers, delivery frequency and the menu, and we will size the cabinets or cold room with the quotation.